Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
1.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37789664

RESUMEN

AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.


Asunto(s)
Fibrilación Atrial , COVID-19 , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Humanos , Terapia de Resincronización Cardíaca/métodos , Tiempo de Internación , COVID-19/epidemiología , Encuestas y Cuestionarios
2.
Open Heart ; 10(2)2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37793674

RESUMEN

OBJECTIVE: To determine the diagnostic yield of a 'high' N-terminal pro-brain natriuretic peptide (NT-proBNP) in patients with suspected heart failure (HF) referred from primary to secondary care. METHODS: In this retrospective study, cardiac diagnoses were quantified in consecutive patients with an NT-proBNP>400 ng/L referred from primary care centres to a specialist HF service. RESULTS: Among 654 consecutive patients (age: 78.5±9.72 years; 45.9% men; left ventricular ejection fraction (LVEF): 55.4±12.5% (mean±SD)), the primary diagnoses were: valvular disease (39.4%), HF (29.2%; 13.3% with LVEF<40%) and atrial fibrillation (AF; 17.3%). In terms of primary or secondary diagnoses, 68% of patients had valve disease, 46.9% had AF and 29.2% had HF. A cardiac diagnosis was made in 85.9%. In multivariable analyses, NT-proBNP predicted HF with LVEF<40% (OR: 10.2, 95% CI: 5.63 to 18.3) and HF with any LVEF (OR: 6.13, 95% CI: 3.79 to 9.93). In canonical linear discriminant analyses, NT-proBNP correctly identified 54.5% of patients with HF. The remainder were misclassified as valvular disease, AF or no cardiac diagnosis. CONCLUSION: Among patients with an NT-proBNP>400 ng/L referred through a primary care HF pathway, most patients had valve disease or AF rather than HF. NT-proBNP cannot discriminate among HF, valve disease and AF. On this basis, NT-proBNP may be best employed in detecting cardiac disease in general rather than HF per se.


Asunto(s)
Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Izquierda , Derivación y Consulta
3.
Europace ; 25(8)2023 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-37622580

RESUMEN

Cardiac resynchronization therapy (CRT) was proposed in the 1990s as a new therapy for patients with heart failure and wide QRS with depressed left ventricular ejection fraction despite optimal medical treatment. This review is aimed first to describe the rationale and the physiologic effects of CRT. The journey of the landmark randomized trials leading to the adoption of CRT in the guidelines since 2005 is also reported showing the high level of evidence for CRT. Different alternative pacing modalities of CRT to conventional left ventricular pacing through the coronary sinus have been proposed to increase the response rate to CRT such as multisite pacing and endocardial pacing. A new emerging alternative technique to conventional biventricular pacing, conduction system pacing (CSP), is a promising therapy. The different modalities of CSP are described (Hirs pacing and left bundle branch area pacing). This new technique has to be evaluated in clinical randomized trials before implementation in the guidelines with a high level of evidence.


Asunto(s)
Terapia de Resincronización Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Trastorno del Sistema de Conducción Cardíaco , Sistema de Conducción Cardíaco
4.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37265253

RESUMEN

AIMS: The past decade has seen an increased delivery of cardiac resynchronization therapy (CRT) for patients with heart failure (HF). We explored whether clinical outcomes after CRT have changed from the perspective of an entire public healthcare system. METHODS AND RESULTS: A national database covering the population of England (56.3 million in 2019) was used to explore clinical outcomes after CRT from 2010 to 2019. A total of 64 698 consecutive patients (age 71.4 ± 11.7 years; 74.8% male) underwent CRT-defibrillation [n = 32 313 (49.7%)] or CRT-pacing [n = 32 655 (50.3%)] implantation. From 2010-2011 to 2018-2019, there was a 76% increase in CRT implantations. During the same period, the proportion of patients with hypertension (59.6-73.4%), diabetes (26.5-30.8%), and chronic kidney disease (8.62-22.5%) increased, as did the Charlson comorbidity index (CCI ≥ 3 from 20.0% to 25.1%) (all P < 0.001). Total mortality decreased at 30 days (1.43-1.09%) and 1 year (9.51-8.13%) after implantation (both P < 0.001). At 2 years, total mortality [hazard ratio (HR): 0.72; 95% confidence interval (CI) 0.69-0.76] and total mortality or HF hospitalization (HR: 0.59; 95% CI 0.57-0.62) decreased from 2010-2011 to 2018-2019, after correction for age, race, sex, device type (CRT-defibrillation or pacing), comorbidities (hypertension, diabetes, chronic kidney disease, and myocardial infarction), or the CCI (HR: 0.81; 95% CI 0.77-0.85). CONCLUSIONS: From the perspective of an entire public health system, survival has improved and HF hospitalizations have decreased after CRT implantation over the past decade. This prognostic improvement has occurred despite an increasing comorbidity burden.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Diabetes Mellitus , Insuficiencia Cardíaca , Hipertensión , Insuficiencia Renal Crónica , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Pronóstico , Hipertensión/diagnóstico , Hipertensión/epidemiología , Hipertensión/terapia , Insuficiencia Renal Crónica/terapia
5.
Pacing Clin Electrophysiol ; 46(7): 665-673, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37221925

RESUMEN

AIMS: Evidence for CRT in adults with congenital heart disease (ACHD) and chronic heart failure is limited, with recommendations for its use extrapolated from the population with structurally normal hearts. This retrospective observational study investigates the efficacy of CRT in this heterogenous group, discussing factors predicting response to CRT. METHODS: Twenty-seven patients with structural ACHD who underwent CRT insertion or upgrade at a tertiary center in the United Kingdom were retrospectively studied. The primary outcome measure was clinical response to CRT, defined as improvement of NYHA class and/or improvement in systemic ventricular ejection fraction by one category. Secondary outcomes included change in QRS duration and adverse events. RESULTS: Thirty-seven percent of patients had a systemic right ventricle (sRV). RBBB was the commonest baseline QRS morphology (40.7%) despite this being an unfavorable characteristic for CRT. Overall, positive response to CRT was demonstrated in 18 patients (66.7%). NYHA class improved in 55.5% following CRT (p = .001) and 40.7% showed improvement in systemic ventricular ejection fraction (p = .118). There were no baseline characteristics that predicted response to CRT, and electrocardiographic measures such as QRS shortening post-CRT was not associated with positive response. Good response rates (60.0%) were demonstrated in those with sRV. CONCLUSION: CRT is efficacious in structural ACHD including in those who do not meet conventional criteria. Extrapolation of recommendations from adults with structurally normal hearts may be inappropriate. Future research should focus on improving patient selection for CRT, for example using techniques to better quantify mechanical dysynchrony and intra-procedural electrical activation mapping in these complex patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiopatías Congénitas , Insuficiencia Cardíaca , Humanos , Adulto , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/terapia , Enfermedad Crónica
6.
Eur J Heart Fail ; 25(6): 902-911, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37092287

RESUMEN

AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.


Asunto(s)
Presión Atrial , Insuficiencia Cardíaca , Humanos , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Presión Esfenoidal Pulmonar
7.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36944529

RESUMEN

AIMS: The optimum timing of cardiac resynchronization therapy (CRT) implantation is unknown. We explored long-term outcomes after CRT in relation to the time interval from a first heart failure hospitalization (HFH) to device implantation. METHODS AND RESULTS: A database covering the population of England (56.3 million in 2019) was used to quantify clinical outcomes after CRT implantation in relation to first HFHs. From 2010 to 2019, 64 968 patients [age: 71.4 ± 11.7 years; 48 606 (74.8%) male] underwent CRT implantation, 57% in the absence of a previous HFH, 12.9% during the first HFH, and 30.1% after ≥1 HFH. Over 4.54 (2.80-6.71) years [median (interquartile range); 272 989 person-years], the time in years from the first HFH to CRT implantation was associated with a higher risk of total mortality [hazard ratio (HR); 95% confidence intervals (95% CI)] (1.15; 95% CI 1.14-1.16, HFH (HR: 1.26; 95% CI 1.24-1.28), and the combined endpoint of total mortality or HFH (HR: 1.19; 95% CI 1.27-1.20) than CRT in patients with no previous HFHs, after co-variate adjustment. Total mortality (HR: 1.67), HFH (HR: 2.63), and total mortality or HFH (HR: 1.92) (all P < 0.001) were highest in patients undergoing CRT ≥2 years after the first HFH. CONCLUSION: In this study of a healthcare system covering an entire nation, delays from a first HFH to CRT implantation were associated with progressively worse long-term clinical outcomes. The best clinical outcomes were observed in patients with no previous HFH and in those undergoing CRT implantation during the first HFH. CONDENSED ABSTRACT: The optimum timing of CRT implantation is unknown. In this study of 64 968 consecutive patients, delays from a first heart failure hospitalization (HFH) to CRT implantation were associated with progressively worse long-term clinical outcomes. Each year from a first HFH to CRT implantation was associated with a 21% higher risk of total mortality and a 34% higher risk of HFH. The best outcomes after CRT were observed in patients with no previous HFHs and in those undergoing implantation during their first HFH.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Inglaterra
8.
J Innov Card Rhythm Manag ; 14(3): 5379-5382, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36998414

RESUMEN

A patient with ischemic cardiomyopathy and an implantable cardioverter-defibrillator underwent an upgrade with an epicardial left ventricular lead, which precipitated recurrent ventricular tachycardia (VT). An electrophysiological study with electroanatomic mapping showed the site of the left ventricular lead to be part of the re-entrant circuit, and substrate modification of an endocardial channel led to the resolution of VT and an improvement in symptoms.

9.
Europace ; 25(4): 1458-1466, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36857597

RESUMEN

AIMS: Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. METHODS AND RESULTS: Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). CONCLUSION: The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Electrocardiografía/métodos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Función Ventricular Izquierda
10.
JACC Cardiovasc Imaging ; 16(5): 628-638, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36752426

RESUMEN

BACKGROUND: Late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) offers the potential to noninvasively characterize the phenotypic substrate for sudden cardiac death (SCD). OBJECTIVES: The authors assessed the utility of infarct characterization by CMR, including scar microstructure analysis, to predict SCD in patients with coronary artery disease (CAD). METHODS: Patients with stable CAD were prospectively recruited into a CMR registry. LGE quantification of core infarction and the peri-infarct zone (PIZ) was performed alongside computational image analysis to extract morphologic and texture scar microstructure features. The primary outcome was SCD or aborted SCD. RESULTS: Of 437 patients (mean age: 64 years; mean left ventricular ejection fraction [LVEF]: 47%) followed for a median of 6.3 years, 49 patients (11.2%) experienced the primary outcome. On multivariable analysis, PIZ mass and core infarct mass were independently associated with the primary outcome (per gram: HR: 1.07 [95% CI: 1.02-1.12]; P = 0.002 and HR: 1.03 [95% CI: 1.01-1.05]; P = 0.01, respectively), and the addition of both parameters improved discrimination of the model (Harrell's C-statistic: 0.64-0.79). PIZ mass, however, did not provide incremental prognostic value over core infarct mass based on Harrell's C-statistic or risk reclassification analysis. Severely reduced LVEF did not predict the primary endpoint after adjustment for scar mass. On scar microstructure analysis, the number of LGE islands in addition to scar transmurality, radiality, interface area, and entropy were all associated with the primary outcome after adjustment for severely reduced LVEF and New York Heart Association functional class of >1. No scar microstructure feature remained associated with the primary endpoint when PIZ mass and core infarct mass were added to the regression models. CONCLUSIONS: Comprehensive LGE characterization independently predicted SCD risk beyond conventional predictors used in implantable cardioverter-defibrillator (ICD) insertion guidelines. These results signify the potential for a more personalized approach to determining ICD candidacy in CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Medios de Contraste , Gadolinio , Volumen Sistólico , Función Ventricular Izquierda , Valor Predictivo de las Pruebas , Muerte Súbita Cardíaca/etiología , Cicatriz/etiología , Cicatriz/complicaciones , Infarto/complicaciones , Imagen por Resonancia Cinemagnética/métodos
11.
Circulation ; 147(9): 759-767, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36848410

RESUMEN

The notion that the risk of sudden cardiac death (SCD) in patients with heart failure (HF) is declining seems to be gaining traction. Numerous editorials and commentaries have suggested that SCD, specifically arrhythmic SCD, is no longer a significant risk for patients with HF on guideline-directed medical therapy. In this review, we question whether the risk of SCD has indeed declined in HF trials and in the real world. We also explore whether, despite relative risk reductions, the residual SCD risk after guideline-directed medical therapy still suggests a need for implantable cardioverter defibrillator therapy. Among our arguments is that SCD has not decreased in HF trials, nor in the real world. Moreover, we argue that data from HF trials, which have not adhered to guideline-directed device therapy, do not obviate or justify delays to implantable cardioverter defibrillator therapy. In this context, we underline the challenges of translating the findings of HF randomized, controlled trials of guideline-directed medical therapy to the real world. We also make the case for HF trials that adhere to current guideline-directed device therapy so that we can better understand the role of implantable cardioverter defibrillators in chronic HF.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control
12.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36607529

RESUMEN

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Asunto(s)
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudios Transversales , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Electrocardiografía , Estimulación Cardíaca Artificial , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 46(2): 114-124, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36385259

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) offer effective therapy for the prevention of sudden cardiac death (SCD) due to ventricular arrhythmias. However, inappropriate shocks have detrimental effects on survival and quality of life. The addition of hemodynamic monitoring may be useful in discriminating clinically important ventricular arrhythmias. OBJECTIVE: In this study, we assess the ability of laser Doppler flowmetry to assess the hemodynamic effect of paced atrial and ventricular arrhythmias using mean arterial blood pressure as the reference. METHODS: In this acute human study in patients undergoing an elective electrophysiological study, laser Doppler flowmetry, arterial blood pressure, and surface ECG were acquired during high-rate atrial and ventricular pacing to simulate supraventricular and ventricular tachycardias. RESULTS: Arterial blood pressure and laser Doppler flow signals correlated well during atrial and ventricular pacing (rho = 0.694, p < .001). The hemodynamic impairment detected by both methods was greater during ventricular pacing than atrial pacing (-1.0% vs. 19.0%, p < .001). Laser Doppler flowmetry performed better than rate alone to identify hemodynamic impairments. CONCLUSION: In this acute study, laser Doppler flowmetry tissue perfusion served as a good surrogate measure for arterial pressure, which could be incorporated into future ICDs.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Fibrilación Atrial/terapia , Calidad de Vida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Muerte Súbita Cardíaca/prevención & control , Rayos Láser
14.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36404397

RESUMEN

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Fascículo Atrioventricular , Estudios Cruzados , Volumen Sistólico , Calidad de Vida , Tolerancia al Ejercicio , Función Ventricular Izquierda , Oxígeno , Resultado del Tratamiento , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos
16.
Open Forum Infect Dis ; 9(8): ofac375, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35959208

RESUMEN

Coinfections are more common in patients with cystic fibrosis and bronchiectasis. Infiltrates on imaging studies are seen more commonly in patients with coinfections, but coinfections did not affect treatment outcomes of pulmonary Mycobacterium avium complex.

17.
Pacing Clin Electrophysiol ; 45(9): 1075-1084, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35899803

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction has been linked to a poor response to cardiac resynchronization therapy (CRT). We sought to determine whether cardiovascular magnetic resonance (CMR)-derived measures of RV function influence clinical outcomes after CRT. METHODS: In this retrospective study, we used CMR to assess pre-implant RV volumes and RV ejection fraction (RVEF) in relation to clinical outcomes after CRT implantation. RESULTS: Among 243 patients (age: 70.3 ± 10.8 years [mean ± SD]; 68.7% male; 121 [49.8%]) with ischemic cardiomyopathy and 122 (50.2%) with nonischemic cardiomyopathy, 141 (58%) after CRT-defibrillation (CRT-D) and 102 (42%) after CRT-pacing (CRT-P), 101 (41.6.0%) patients died, 61 (25.1%) from cardiac causes and 24 (9.88%) from noncardiac causes, over 5.87 years (median; interquartile range: 4.35-7.73). Two (0.82%) patients underwent cardiac transplantation and four (1.64%) had a left ventricular assist device (LVAD). A total of 41 (16.9%) met the composite endpoint of sudden cardiac death (SCD), ventricular tachycardia, or ventricular fibrillation. In univariate analyses, no measure of RV function was associated with total mortality or the arrhythmic endpoint. RVEF was associated with cardiac mortality on univariate analyses (HR per 10%: 0.82, 95% CI 0.70-0.96), but not on multivariate analyses that included left ventricular ejection fraction. CONCLUSIONS: There is no relationship between measures of RV function, such as RV volumes and RVEF, and the long-term clinical outcome of CRT. These findings indicate that such measures should not be considered in patient selection.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Insuficiencia Cardíaca , Disfunción Ventricular Derecha , Anciano , Anciano de 80 o más Años , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Derecha/terapia , Función Ventricular Izquierda , Función Ventricular Derecha
19.
Front Cardiovasc Med ; 9: 901267, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35647062

RESUMEN

The aim of the SYNSEQ (Left Ventricular Synchronous vs. Sequential MultiSpot Pacing for CRT) study was to evaluate the acute hemodynamic response (AHR) of simultaneous (3P-MPP syn) or sequential (3P-MPP seq) multi-3-point-left-ventricular (LV) pacing vs. single point pacing (SPP) in a group of patients at risk of a suboptimal response to cardiac resynchronization therapy (CRT). Twenty five patients with myocardial scar or QRS ≤ 150 or the absence of LBBB (age: 66 ± 12 years, QRS: 159 ± 12 ms, NYHA class II/III, LVEF ≤ 35%) underwent acute hemodynamic assessment by LV + dP/dtmax with a variety of LV pacing configurations at an optimized AV delay. The change in LV + dP/dt max (%ΔLV + dP/dt max) with 3P-MPP syn (15.6%, 95% CI: 8.8%-22.5%) was neither statistically significantly different to 3P-MPP seq (11.8%, 95% CI: 7.6-16.0%) nor to SPP basal (11.5%, 95% CI:7.1-15.9%) or SPP mid (12.2%, 95% CI:7.9-16.5%), but higher than SPP apical (10.6%, 95% CI:5.3-15.9%, p = 0.03). AHR (defined as a %ΔLV + dP/dt max ≥ 10%) varied between pacing configurations: 36% (9/25) for SPP apical, 44% (11/25) for SPP basal, 54% (13/24) for SPP mid, 56% (14/25) for 3P-MPP syn and 48% (11/23) for 3P-MPP seq.Fifteen patients (15/25, 60%) had an AHR in at least one pacing configuration. AHR was observed in 10/13 (77%) patients with a LBBB but only in 5/12 (42%) patients with a non-LBBB (p = 0.11). To conclude, simultaneous or sequential multipoint pacing compared to single point pacing did not improve the acute hemodynamic effect in a suboptimal CRT response population. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT02914457.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...